Journal cover Journal topic
Hydrology and Earth System Sciences An interactive open-access journal of the European Geosciences Union
Hydrol. Earth Syst. Sci., 21, 5009-5030, 2017
https://doi.org/10.5194/hess-21-5009-2017
© Author(s) 2017. This work is distributed under
the Creative Commons Attribution 3.0 License.
Research article
06 Oct 2017
Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity
Martin Schrön1,2, Markus Köhli1,3,4, Lena Scheiffele5, Joost Iwema6, Heye R. Bogena7, Ling Lv8, Edoardo Martini1, Gabriele Baroni2,5, Rafael Rosolem6,9, Jannis Weimar3, Juliane Mai2,10, Matthias Cuntz2,11, Corinna Rebmann2, Sascha E. Oswald5, Peter Dietrich1, Ulrich Schmidt3, and Steffen Zacharias1 1Dept. Monitoring and Exploration Technologies, Helmholtz Centre for Environmental Research – UFZ, Leipzig, Germany
2Dept. Computational Hydrosystems, Helmholtz Centre for Environmental Research – UFZ, Leipzig, Germany
3Physikalisches Institut, Heidelberg University, Heidelberg, Germany
4Physikalisches Institut, University of Bonn, Bonn, Germany
5Institute of Earth and Environmental Science, University of Potsdam, Postdam, Germany
6Faculty of Engineering, University of Bristol, Bristol, UK
7Agrosphere Institute (IBG-3), Forschungszentrum Jülich GmbH, Jülich, Germany
8Dept. of Plants, Soils and Climate, Utah State University, Logan, USA
9Cabot Institute, University of Bristol, Bristol, England
10Dept. of Civil and Environmental Engineering, University of Waterloo, Waterloo, Canada
11INRA, Université de Lorraine, UMR1137, Ecology et Ecophysiologie Forestière, Champenoux, France
Abstract. In the last few years the method of cosmic-ray neutron sensing (CRNS) has gained popularity among hydrologists, physicists, and land-surface modelers. The sensor provides continuous soil moisture data, averaged over several hectares and tens of decimeters in depth. However, the signal still may contain unidentified features of hydrological processes, and many calibration datasets are often required in order to find reliable relations between neutron intensity and water dynamics. Recent insights into environmental neutrons accurately described the spatial sensitivity of the sensor and thus allowed one to quantify the contribution of individual sample locations to the CRNS signal. Consequently, data points of calibration and validation datasets are suggested to be averaged using a more physically based weighting approach. In this work, a revised sensitivity function is used to calculate weighted averages of point data. The function is different from the simple exponential convention by the extraordinary sensitivity to the first few meters around the probe, and by dependencies on air pressure, air humidity, soil moisture, and vegetation. The approach is extensively tested at six distinct monitoring sites: two sites with multiple calibration datasets and four sites with continuous time series datasets. In all cases, the revised averaging method improved the performance of the CRNS products. The revised approach further helped to reveal hidden hydrological processes which otherwise remained unexplained in the data or were lost in the process of overcalibration. The presented weighting approach increases the overall accuracy of CRNS products and will have an impact on all their applications in agriculture, hydrology, and modeling.

Citation: Schrön, M., Köhli, M., Scheiffele, L., Iwema, J., Bogena, H. R., Lv, L., Martini, E., Baroni, G., Rosolem, R., Weimar, J., Mai, J., Cuntz, M., Rebmann, C., Oswald, S. E., Dietrich, P., Schmidt, U., and Zacharias, S.: Improving calibration and validation of cosmic-ray neutron sensors in the light of spatial sensitivity, Hydrol. Earth Syst. Sci., 21, 5009-5030, https://doi.org/10.5194/hess-21-5009-2017, 2017.
Publications Copernicus
Download
Short summary
A field-scale average of near-surface water content can be sensed by cosmic-ray neutron detectors. To interpret, calibrate, and validate the integral signal, it is important to account for its sensitivity to heterogeneous patterns like dry or wet spots. We show how point samples contribute to the neutron signal based on their depth and distance from the detector. This approach robustly improves the sensor performance and data consistency, and even reveals otherwise hidden hydrological features.
A field-scale average of near-surface water content can be sensed by cosmic-ray neutron...
Share